FULLRIVER currently provides above eight product series to our customers around the world. Beyond that, FULLRIVER has "Make-to-Order" capability to design and manufacture special type batteries that customers need. Please contact us directly if you have special technical or dimensional requirements for the batteries you want to order.
DCG SERIES
 
DCG Series: Gel Batteries for Deep Cycle Service
Introduction General Features Application
Construction Terminal and accessories Charge Characteristic

Fullriver
Type

Industry
Ref.

Capacity Amp HoursA
(AH)

Capacity
Minutes

Cranking
Performance
Length Width Height Total Height Weight (Approx.)

Terminal
Type

Pallet
QTY

5 Hr
rate

20 Hr
rate

100 Hr
rate

@25B
Am ps

CCAC
@0H

CA D
@32H

mm in mm in mm in mm in kg pound
6V DEEP CYCLE GEL BATTERY
DCG190-6 GC2 155 190 198 390 575 825 260 10.24 181 7.13 255 10.04 275 10.83 29.80 65.70

AP

28

DCG200-6 (DIN) 167 200 230 / / / 243 9.57 188 7.40 275 10.83 275 10.83 31.60 69.67

AP

30

DCG280-6 902 234 280 310 / / / 315 12.40 180 7.09 339.5 13.37 355 13.98 46.20 101.85

AP

22

8V DEEP CYCLE GEL BATTERY
DCG140-8 GC8 114 140 160 / / / 260 10.24 182 7.17 268 10.55 272 10.71 29.40 64.82

M8

28

12V DEEP CYCLE GEL BATTERY
DCG24-12 N/A 22 24 27 / / / 166 6.54 126 4.96 175 6.89 174 6.89 9.00 19.84 M5 114
DCG26-12 N/A 22.5 26 29 / / / 165 6.50 176 6.93 125 4.92 125 4.92 9.10 20.06 M6 120
DCG32-12 U1 24 32 37 / / / 197 7.76 131 5.16 167 6.57 171 6.73 10.60 23.37 M6 100
DCG40-12 U1L 33 40 46 / / / 198 7.80 166 6.54 171 6.73 171 6.73 13.5 29.76 M6 88

DCG50-12

(DIN/L2) 42 50 57 / / / 241 9.49 175 6.89 190 7.48 190 7.48 18.00 39.68 AP 64

DCG51-12

22NF 43 51 58 / / / 229 9.02 138 5.43 208 8.19 242 8.35 17.10 37.70

M6

63

DCG55-12

48 46 55 63 / / / 271 10.67 170 6.69 189 7.44 189 7.44 19 41.89

AP

48

DCG56-12

(DIN/L3) 47 56 65 / / / 278 10.94 175 6.89 190 7.48 190 7.48 21.10 46.52

AP

48

DCG65-12

24 55 65 76 147 330 460 256 10.08 170 6.69 206 8.11 210 8.27 21.90 48.28

M6

48

DCG75-12

(DIN/L5) 63 75 86 / / / 353 13.90 175 6.89 190 7.48 190 7.48 24.90 54.90

AP

36

DCG77-12

24 66 77 85 / / / 260 10.24 169 6.65 241 8.31 245 8.46 24.20 53.35

M6

48

DCG79-12

30H 70 79 87 / / / 328 12.91 169 6.65 242 8.35 232 9.13 29.10 64.15

AP

36

DCG88-12

27 73.5 88 101 / / / 307 12.09 169 6.65 211 8.31 215 8.46 28.40 62.61

M6

36

DCG100-12

31 84 100 110 200 445 620 329 12.95 171 6.73 227 8.94 247 9.72 31.70 69.89

AP

36

DCG110-12

6T 93.5 110 120 / / / 286 11.26 269 10.59 210 8.27 230 9.06 37.60 82.89

AP

27

DCG120-12A

5SHP 105 120 132 / / / 341 13.43 172 6.77 264 10.39 283 11.14 38.6 85.10

AP

24

DCG120-12B

GC12 105 120 132 / / / 327 12.87 182 7.17 269 10.59 289 11.38 39.5 87.08

AP

22
DCG135-12 N/A 112 135 155 / / / 482 18.98 170 6.69 223 8.78 229 9.02 42.5 93.70 M8 24
DCG160-12 4D 133 160 183 / / / 527 20.75 224 8.82 234 9.21 239 9.41 53.4 117.73 M8 18

DCG170-12

921 142 170 195 / / / 381 15.00 178 7.01 352 13.86 358 14.08 57.4 126.55

M8

20

DCG180-12

4D 150 180 206 / / / 527 20.75 224 8.82 234 9.21 239 9.41 62.6 138.01

M8

18
DCG200-12 8D 167 200 228 / / / 522 20.55 239 9.41 220 8.66 224 8.82 66.5 146.61 M8 18

DCG220-12

8D 184 220 258 / / / 527 20.75 287 11.30 235 9.25 257 10.11 75.1 165.57

DT

12

DCG240-12

8D 195 240 280 / / / 527 20.75 287 11.30 235 9.25 257 10.11 79.7 175.71

DT

12

    A.The amount of amp-hours (AH) a battery can deliver when discharged at a constant rate at 80F (27C) for the 20 Hr? and 100 Hr rates and? 86F (30C) for the 5-Hr rate and maintain a voltage above 1.75 V/cell. Capacities are based on peak performance.

    B.RC (Reserve Capacity) - the number of minutes a battery can be discharged at 25 amps at 27 (80H) and maintain a voltage above 1.75v/cell.

    C.CCA(Cold Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintained for 30 seconds at 0H(-17.8)at a voltage above 1.2v/cell.

    D.CA(Cranking Amps) - the discharge load in amperes which a new, fully charged battery can maintained for 30 seconds at 32H 0) at a voltage above 1.2v/cell.

    E.Terminal type CPlease see our terminal configurations

    F.Dimensions are based on maximum size. Dimensions may vary depending on type of handle or terminal. Batteries to be mounted with .5 inches (12.7mm) spacing minimum.